- Introduction
- Access control
- Licensing
- Unified Pricing
- Flex Plan
- Frequently asked questions

IXP overview guide
The following table shows the features available in UiPath® IXP based on the Platform plan:
Feature | Feature description |
Free | Basic Trial | Standard Trial | Enterprise Trial | Basic | Standard | Enterprise |
---|---|---|---|---|---|---|---|---|
Communications data (Communications Mining) | Access to Communications Mining capabilities, except for CMEK. For more details, check Metering and charging logic (Unified Pricing). | No | Yes | Yes | Yes | Yes | Yes | Yes |
Unstructured and complex documents | Access to the Unstructured and complex documents capability. | No | Yes | Yes | Yes | Yes | Yes | Yes |
The following table shows which user licenses provide access to IXP:
Unlicensed | Express | Basic | Plus | Pro |
---|---|---|---|---|
No | No | Yes | Yes | Yes |
Measuring consumption
The UiPath® IXP utilization is measured based on the consumption rate of units.
Consuming units
In IXP, units are consumed at a rate of 0.2 Platform Units per chargeable action:
- Per message uploaded, modified, or predicted (Communications Mining).
- Per page at run time, no charge at design time (Unstructured and complex documents).
Platform Units consumption
This section outlines how metering and charging for Platform Units are determined based on the type of operation you perform:
Product | Capability | Charge details | Activity or model | Platform Units consumed |
---|---|---|---|---|
Intelligent Xtraction and Processing (IXP) | Communications Data (Communications Mining) | Per message uploaded, modified or predicted | Classification and extraction | 0.2 |
Intelligent Xtraction and Processing (IXP) | Unstructured and Complex Document s project | Per page at run time, no charge at design time | Intelligent Extraction | 0.2 |
Metering scenarios
This section describes what happens when different projects are used together on the same document.
The following table provides an example of the consumed units based only on the number of pages you extract:
Input | Classification | Extraction | Extraction | Platform Units consumed |
---|---|---|---|---|
50 page document | N/A | IXP | N/A | 10 |
50 page document | N/A | IXP | Modern | 20 |
50 page document | N/A | IXP | Form Extractor | 12 |
50 page document | N/A | IXP | Forms AI | 20 |
50 page document | N/A | IXP | IXP | 20 |
50 page document | N/A | IXP | Classic | 20 |
50 page document | N/A | IXP | OOB endpoint | 20 |
50 page document | N/A | IXP | Gen Extractor | 20 |
The following table provides an example of the consumed units based on the number of pages you classify, and extract using IXP:
Input | Classification | Extraction | Platform Units consumed |
---|---|---|---|
50 page document | Modern | IXP | 20 |
50 page document | IKC | IXP (5 pages) | 1.2 |
50 page document | Gen Class | IXP | 20 |
50 page document | Classic | IXP | 10.2 |
50 page document | OOB endpoint | IXP | 10.2 |
Input | Classification | Extraction | Extraction | Platform Units consumed |
---|---|---|---|---|
50 page document | Modern | IXP | Modern | 20 |
50 page document | Modern | IXP | Form Extractor | 22 |
50 page document | Modern | IXP | Forms AI | 30 |
50 page document | Modern | IXP | IXP | 30 |
50 page document | Modern | IXP | Classic | 30 |
50 page document | Modern | IXP | OOB endpoint | 30 |
50 page document | Modern | IXP | Gen Extractor | 20 |
50 page document | IKC | IXP (5 pages) | Modern (5 pages) | 2.2 |
50 page document | IKC | IXP (5 pages) | Form Extractor (5 pages) | 1.4 |
50 page document | IKC | IXP (5 pages) | Forms AI (5 pages) | 2 |
50 page document | IKC | IXP (5 pages) | IXP (5 pages) | 2 |
50 page document | IKC | IXP (5 pages) | Classic (5 pages) | 2.2 |
50 page document | IKC | IXP (5 pages) | OOB endpoint (5 pages) | 2.2 |
50 page document | IKC | IXP (5 pages) | Gen Extractor (5 pages) | 2.2 |
50 page document | Gen Class | IXP | Modern | 20 |
50 page document | Gen Class | IXP | Form Extractor | 22 |
50 page document | Gen Class | IXP | Forms AI | 30 |
50 page document | Gen Class | IXP | IXP | 30 |
50 page document | Gen Class | IXP | Classic | 30 |
50 page document | Gen Class | IXP | OOB endpoint | 30 |
50 page document | Gen Class | IXP | Gen Extractor | 20 |
50 page document | Classic | IXP | Modern | 20.2 |
50 page document | Classic | IXP | Form Extractor | 12.2 |
50 page document | Classic | IXP | IXP | 20.2 |
50 page document | Classic | IXP | Classic | 20.2 |
50 page document | Classic | IXP | OOB endpoint | 20.2 |
50 page document | Classic | IXP | Gen Extractor | 20.2 |
50 page document | OOB endpoint | IXP | Modern | 20.2 |
50 page document | OOB endpoint | IXP | Form Extractor | 12.2 |
50 page document | OOB endpoint | IXP | Forms AI | 30 |
50 page document | OOB endpoint | IXP | IXP | 30 |
50 page document | OOB endpoint | IXP | Classic | 20.2 |
50 page document | OOB endpoint | IXP | OOB endpoint | 20.2 |
50 page document | OOB endpoint | IXP | Gen Extractor | 20.2 |