
Automation Suite release notes
2022.4.11
Release date: March 11, 2024
Before upgrading to Automation Suite 2022.4.11, keep the following guidelines in mind:
- If your current version is 2022.4.7 or later, you can directly upgrade to 2022.4.11.
- If you are on any 2021.10 version, you must first upgrade to 2022.4.7. Once this upgrade is successful, then proceed to upgrade to 2022.4.11.
If you plan to upgrade Automation Suite 2022.4.11 to 2023.10.2, it is mandatory to follow the How to upgrade from Automation Suite 2022.10.10 and 2022.4.11 to 2023.10.2 procedure.
Erratum - Added March 25, 2024: We now support Microsoft SQL Server 2022.
opt/UiPathAutomationSuite
installation folder.
We have expanded our OS support to include RHEL 8.9, alongside existing support for 8.6 and 8.8 versions.
net.ipv4.conf.all.rp_filter
is set to 0
.
For more on the prerequisite script, see Validating the prerequisites.
We continue to provide security updates and patches to address Common Vulnerabilities and Exposures (CVEs).
-
Erratum - added October 11, 2024: In a proxy environment, if the proxy server uses the same port as the TCP port of any other service in the Istio service mesh, such as port 8080, pods cannot communicate with the FQDN. The issue causes the following error:
System.Net.Http.HttpRequestException: The proxy tunnel request to proxy 'http://<proxyFQDN>:8080/' failed with status code '404'.
System.Net.Http.HttpRequestException: The proxy tunnel request to proxy 'http://<proxyFQDN>:8080/' failed with status code '404'.To fix the issue, see the Troubleshooting section.
-
Erratum - added August 29, 2024: We have identified certain vulnerabilities associated with the usage of weak ciphers in TLS 1.2. For details on how to mitigate the issue, see How to address weak ciphers in TLS 1.2.
-
Erratum - added April 19, 2024: In certain situations, Ceph metrics and alerts are missing from the monitoring dashboards. To fix the issue, see the Troubleshooting section.
-
Erratum - added April 19, 2024: False positive CephMgrIsAbsent alerts are displayed even though there are no storage issues.
-
Occasionally, when performing a clean installation or upgrade to Automation Suite 2022.4.11, you may encounter a restart issue disrupting RKE2. For details, see RKE2 fails during installation and upgrade.
We recommend that you regularly check the deprecation timeline for any updates regarding features that will be deprecated and removed.
To find out what has changed on each Automation Suite product, visit the following links.
If the product is greyed out, this new Automation Suite version does not bring any changes to it.
DISCOVER | BUILD | MANAGE | ENGAGE |
Automation Hub 2022.4.9 | AI Center 2022.4.11 | Action Center 2022.4.10 | |
Task Mining 2022.4.10 | AI Computer Vision 2022.4.0 | Insights 2022.4.11 | Apps 2022.4.7 |
Document Understanding 2022.4.11 | Orchestrator 2022.4.13 | ||
Test Manager 2022.4.10 | |||
This Automation Suite release bundles the following internal components:
Component |
Version |
---|---|
RKE2 |
1.26.11 |
ArgoCD |
2.2.5 |
rook-ceph |
1.8.9 |
cert-manager |
1.9.1 |
rancher |
2.7.6 |
rancher-istio | 102.2.0-up1.17.2 |
longhorn |
1.4.3 |
longhorn-crd |
1.1.100 |
reloader |
0.0.129 |
csi-driver-smb |
v1.10.0 |
rabbitmq-operator |
1.5.0 |
redis-operator |
7.2.4-7 |
redis-cluster |
7.2.4-64 |
mongodb |
4.4.4-ent |
docker_registry |
2.8.1 |
- Upgrade considerations
- Upgrading to Automation Suite 2022.4.11
- Upgrading from Automation Suite 2022.4.11
- Support for Microsoft SQL Server 2022
- New requirement for installation folder
- New RHEL version support
- New prerequisites validation check
- Security enhancements
- Known issues
- Deprecation timeline
- Bundling details
- Product versions
- Internal third-party component versions