- Getting started
- Project management
- Project operations and utilities
- Test Manager settings
- ALM tool integration
- API integration

Test Manager user guide
RFC connection
linkTo create an integration between your Test Manager project and your SAP system to collect data periodically, using an RFC connection to your SAP system, follow these steps:
1. Integrate SAP NetWeaver RFC SDK - Automation Suite
link- Test Manager installed with Automation Suite.
- SAP Netweaver RFC SDK 7.50
- Test Manager migrator shell script. Make sure you meet the
following environment requirements:
kubectl
configured with a connection to the Automation suite cluster.jq
(install it using the following command:yum install jq
)argocd
CLI (Installation - Argo CD - Declarative GitOps for Kubernetes)rclone
(Install Rclone)
- Download the SAP Netweaver RFC SDK 7.50 and extract it.
- Navigate to the
lib
folder and save this folder path.In thelib
folder you'll find the libraries as.so
files. -
Copy the libraries to your Automation Suite storage, using the Test Manager migrator shell script.
- For External object
storages - run the following command in
Powershell:
./testmanager_migrator.sh -sap <storage_folder_location> -y
./testmanager_migrator.sh -sap <storage_folder_location> -y - For InCluster Ceph
Object storages - run the following command in
Powershell:
./testmanager_migrator.sh -sap <storage_folder_location> -is -y
./testmanager_migrator.sh -sap <storage_folder_location> -is -y
Replacestorage_folder_location
with the path you saved at Step 2. - For External object
storages - run the following command in
Powershell:
- Check if you can access Test Manager inside Automation Suite.
- You can create a custom connection with your SAP system in a Test Manager project.
2. Create the SAP connection
link- Open your project in Test Manager, and go to Project Settings > Integration.
- Select SAP from the New
Connection dropdown.
The Edit connection dialog pops up.
- Fill in the fields according to the
data from your SAP system:
- Name - name the integration between Test Manager and SAP.
- Description - describe the integration between Test Manager and SAP.
- From Data Source select
Connect to SAP instance with RFC:
- Application Server—IP
address or URL that your SAP system is working on.
For example, a URL can have the following format:
mysapserver.com
. - System name—three-letter SAP system ID.
- Instance Number—SAP system number.
- Client—SAP client to log into.
- User—SAP user name.
- Password—SAP password.
- Polling Interval—time interval when data is brought from the SAP system. The minimum value for this is one hour.
Figure 1. Create new connection with RFC
- Application Server—IP
address or URL that your SAP system is working on.
- After you finish the configuration of the integration, select Save.
- Refresh your project. The Heatmap page appears in the left-hand menu of your Test Manager project.
2. Configure Change Impact Analysis
linkAfter you set up RFC connection, choose how to enable Change Impact Analysis, and define which SAP system it connects to:
- Open your existent SAP connection, or select SAP from the New Connection dropdown list.
- Select Change Impact Analysis connection.
- Under Impact Analysis Access
select the view tabs corresponding to SAP change types that you want to display in
your Change Impact Analysis:
- UI: Selected by default, displays transactions impacted by the selected transports.
- API: Displays the technical interfaces impacted by the selected transports, such as SAP BAPI, SAP RFC, SAP QUERY, and SAP IDOC.
- Security: Displays security transactions and corresponding users impacted by the selected transports.
-
Under Connection Source select one of the following:
- Same as Heatmap: Keep
the same SAP connection details that you are using for the Heatmap.
This means both functionalities will collect data from the same SAP system.
- New connection: Create
a separate SAP connection for Change Impact Analysis. This option
allows you to use different authentication details while maintaining the
same connection type as the Heatmap.
Note: We recommend you to connect the Heatmap to your production system and Change Impact Analysis to your quality system for optimal risk evaluation.
Follow the same steps as above, for creating a web service connection.
- If your Heatmap connection
uses a CSV file:
You must create a new connection for Change Impact Analysis.
Follow the same steps for creating either an RFC or .
- Same as Heatmap: Keep
the same SAP connection details that you are using for the Heatmap.